DC 1800 H EX Stainless Steel

The professionals choice in ATEX zone 22

  • Suitable for operation in environments with potentially combustible dust (non-conductive); stainless steel design enables the use of alkaline wash solutions; high resistance to acids.
  • Cleaning accessories from Dustcontrol are also available to meet the ATEX Zone 22 regulations
  • IP54
1-phase 1-phase
Ex Ex
H 3rd Party H 3rd Party
IP54 IP54
DGUV Test DGUV Test
Get a request
  • Model Part no
    Request
  • DC 1800 H SS EX 230V 50/60Hz EU
    124004
    Request
  • DC 1800 H SS EX 230V 50/60Hz DE
    124004-2
    Request
  • DC 1800 H SS EX 115V 60Hz USA, CAN
    124005
    Request
  • DC 1800 H SS EX 230V 50/60Hz CH
    124008-1
    Request
  • DC 1800 H SS EX 230V 50/60Hz UK
    124011
    Request

Dustcontrol’s DC 1800/2800 H EX SS are valued both for its easy handling and capacity when being used to reduce the risks of potential dust explosions in ATEX Zone 22 (non-conductive dust). However, there are areas with high hygienic demands (e g the food processing industry), which surpass the abilities of our standard DC 1800/2800 H EX SS. Suitable for operation in environments with potentially combustible dust (non-conductive); stainless steel design enables the use of alkaline wash solutions; high resistance to acids.

Supplied with (Part No) DC1800 / DC 2800 H EX Stainless Steel:

  • Suction hose, antistatic Ø38 ATEX (2027)
  • Floor nozzle 370 A-38, ESD-certified (7235E)
  • Suction pipe Ø38 mm/1.5” (7257)
  • Plastic bag (42951)
  • Fine filter, polyester (42028-01)
  • HEPA H13 filter (42027)
HxWxD [mm]

8430x400x400

(US only) HxWxD [in]

33x16x16

Weight [kg]

16.5

(US only) Weight [lb]

31

Inlet Ø [mm]

50

(US only) Inlet Ø [in]

2

Hose length Ø38mm [m]

5

(US only) Hose length Ø38mm/1.5" [m/ft]

5/16.4

Collecting container [l]

20

(US only) Collecting container [l/gal]

20/5.3

Max. flow fan (EU) 230V [m3/h]

200

(UK only) Max. flow fan (UK) 115V [m3/h]

200

(UK only) Max. flow fan (UK) 230V [m3/h]

200

(US only) Max. flow fan (US/CAN) 115V [CFM/m3/h]

117.7/200

Negative pressure max. (EU) [kPa]

27

(UK only) Negative pressure max. (UK) [kPa]

27

(US only) Negative pressure max. (US/CAN) [inwg/kPa]

108.4/27

Power (EU) 230V [W]

1500

(UK only) Power (UK) 115V [W]

1500

(UK only) Power (UK) 230V [W]

1500

(US only) Power (US/CAN) 115V [Hp/W]

2/1500

Fine filter polyester, area [m2]

1.5

(US only) Fine filter polyester, area [ft2]

16.15

Degree of separation fine filter, EN 60335-2-69, Class M [%]

99.9

HEPA filter, area [m2]

0.85

(US only) HEPA filter, area [ft2]

9.15

Filter classification HEPA filter, EN 1822-1

HEPA H13

Degree of separation machine, EN 60335-2-69, Appendix A-A, Class H [%]

99.995

Max. sound level [dB(A)]

70

EX-Line Dust Extractors, Industry, Mobile Dust Extractors, Single-Phase Dust Extractors

DC 1800 H EX Stainless Steel

The professionals choice in ATEX zone 22

  • Suitable for operation in environments with potentially combustible dust (non-conductive); stainless steel design enables the use of alkaline wash solutions; high resistance to acids.
  • Cleaning accessories from Dustcontrol are also available to meet the ATEX Zone 22 regulations
  • IP54
1-phase 1-phase
Ex Ex
H 3rd Party H 3rd Party
IP54 IP54
DGUV Test DGUV Test
Get a request
  • Model Part no
    Request
  • DC 1800 H SS EX 230V 50/60Hz EU
    124004
    Request
  • DC 1800 H SS EX 230V 50/60Hz DE
    124004-2
    Request
  • DC 1800 H SS EX 115V 60Hz USA, CAN
    124005
    Request
  • DC 1800 H SS EX 230V 50/60Hz CH
    124008-1
    Request
  • DC 1800 H SS EX 230V 50/60Hz UK
    124011
    Request

Related products

Dustcontrol, Box 3088, Kumla Gårdsväg 14, 145 03 Norsborg, SWEDEN